EMS Control​

Built on inverter capabilities, the Solinteg OpenAPI provides the following two control modes for different EMS control scenarios.

ToU Mode​

Short for "Time of Use". The inverter accepts work plans for today/tomorrow and executes different sub working modes in different time periods according to the plan delivered in advance. Depending on the model and firmware version, inverters support hourly and 15-minute granularity control.

EMS Mode​

Includes two working modes: EMS AC Control & EMS Battery Control. It is a real-time control mode that Solinteg inverters provide for third-party EMS platforms. Through this mode, a third-party EMS platform can directly control the inverter's power output. This mode has high requirements on network stability.

The control frequency is recommended to be once every 5~10 s. High-frequency control will accelerate chip wear on the hardware. Users need to weigh this themselves.