Inverter Telemetry Data
- Please note that fields marked with Deprecated should be discontinued as soon as possible, as they may be removed in future versions. Please exercise caution when using them.
- If the field is not reported by the device, the value of the field is null.
| Field | Type | Unit | Remark | Device Type |
|---|---|---|---|---|
| invSn | String | — | Device SN | On-Grid Inverter / Hybrid Inverter |
| creationDate | String | — | Device data upload time to server (default Z time zone) | On-Grid Inverter / Hybrid Inverter |
| rtcTime | String | — | Device local time | On-Grid Inverter / Hybrid Inverter |
| dataLoggerSN | String | — | Superior intelligent device SN (Smart Meter / DataLogger) When there is a physical connection between the inverter and the smart meter, the value is shown as the smart device's SN | On-Grid Inverter / Hybrid Inverter |
| dataLoggerTime | String | — | Data reporting time for Superior Intelligent Device | On-Grid Inverter / Hybrid Inverter |
| modelType | String | — | Device Model | On-Grid Inverter / Hybrid Inverter |
| alarms | String[] | — | Current device alarm information, Alarm Code Explanation | On-Grid Inverter / Hybrid Inverter |
| rssi | String | — | Signal strength; the closer to 100, the stronger the signal | On-Grid Inverter / Hybrid Inverter |
| saftyCountryCode | String | — | Safety code | On-Grid Inverter / Hybrid Inverter |
| timeTotal | Number | H | Total power generation time | On-Grid Inverter / Hybrid Inverter |
| workStatus | Number | — | Inverter status 0/1/4 Standby 2 On-Grid 3 Fault 5 Off-grid power generation | On-Grid Inverter / Hybrid Inverter |
| workStatus2 | Number | — | If the last bit is not 1, the anti-reverse flow is switched off and the device is present for grid connection | On-Grid Inverter / Hybrid Inverter |
| faultFlag1 | Number | — | Fault FLAG1 | On-Grid Inverter / Hybrid Inverter |
| faultFlag2 | Number | — | Fault FLAG2 | On-Grid Inverter / Hybrid Inverter |
| faultFlag3 | Number | — | Fault FLAG3 | On-Grid Inverter / Hybrid Inverter |
| faultArmFlag1 | Number | — | ARM Fault FLAG1 | On-Grid Inverter / Hybrid Inverter |
| faultArmFlag2 | Number | — | ARM Fault FLAG2 | On-Grid Inverter / Hybrid Inverter |
| meterStatus | Decimal | — | Meter detection status | On-Grid Inverter / Hybrid Inverter |
| temperature1 | Decimal | ℃ | Temperature 1 | On-Grid Inverter / Hybrid Inverter |
| temperature2 | Decimal | ℃ | Temperature 2 | On-Grid Inverter / Hybrid Inverter |
| temperature3 | Decimal | ℃ | Temperature 3 | On-Grid Inverter / Hybrid Inverter |
| temperature4 | Decimal | ℃ | Temperature 4 | On-Grid Inverter / Hybrid Inverter |
| busVoltage | Decimal | V | Busbar voltage | On-Grid Inverter / Hybrid Inverter |
| fGrid | Decimal | Hz | Grid frequency | On-Grid Inverter / Hybrid Inverter |
| fgrid Deprecated | Decimal | Hz | Grid frequency | On-Grid Inverter / Hybrid Inverter |
| pMeterTotal | Decimal | kW | Total power of the meter | On-Grid Inverter / Hybrid Inverter |
| pmeterTotal Deprecated | Decimal | kW | Total power of the meter | On-Grid Inverter / Hybrid Inverter |
| pMeterPhaseA | Decimal | kW | A-phase meter power | Hybrid Inverter |
| pmeterPhaseA Deprecated | Decimal | kW | A-phase meter power | Hybrid Inverter |
| pMeterPhaseB | Decimal | kW | B-phase meter power | Hybrid Inverter |
| pmeterPhaseB Deprecated | Decimal | kW | B-phase meter power | Hybrid Inverter |
| pMeterPhaseC | Decimal | kW | C-phase meter power | Hybrid Inverter |
| pmeterPhaseC Deprecated | Decimal | kW | C-phase meter power | Hybrid Inverter |
| vGridPhaseA | Decimal | V | Grid phase A voltage | On-Grid Inverter / Hybrid Inverter |
| vgridPhaseA Deprecated | Decimal | V | Grid phase A voltage | On-Grid Inverter / Hybrid Inverter |
| iGridPhaseA | Decimal | A | Grid phase A current | On-Grid Inverter / Hybrid Inverter |
| igridPhaseA Deprecated | Decimal | A | Grid phase A current | On-Grid Inverter / Hybrid Inverter |
| vGridPhaseB | Decimal | V | Grid phase B voltage | On-Grid Inverter / Hybrid Inverter |
| vgridPhaseB Deprecated | Decimal | V | Grid phase B voltage | On-Grid Inverter / Hybrid Inverter |
| iGridPhaseB | Decimal | A | Grid phase B current | On-Grid Inverter / Hybrid Inverter |
| igridPhaseB Deprecated | Decimal | A | Grid phase B current | On-Grid Inverter / Hybrid Inverter |
| vGridPhaseC | Decimal | V | Grid phase C voltage | On-Grid Inverter / Hybrid Inverter |
| vgridPhaseC Deprecated | Decimal | V | Grid phase C voltage | On-Grid Inverter / Hybrid Inverter |
| iGridPhaseC | Decimal | A | Grid phase C current | On-Grid Inverter / Hybrid Inverter |
| igridPhaseC Deprecated | Decimal | A | Grid phase C current | On-Grid Inverter / Hybrid Inverter |
| vGridAb | Decimal | V | Grid AB line voltage | On-Grid Inverter / Hybrid Inverter |
| vgridAb Deprecated | Decimal | V | Grid AB line voltage | On-Grid Inverter / Hybrid Inverter |
| vGridBc | Decimal | V | Grid BC line voltage | On-Grid Inverter / Hybrid Inverter |
| vgridBc Deprecated | Decimal | V | Grid BC line voltage | On-Grid Inverter / Hybrid Inverter |
| vGridCa | Decimal | V | Grid CA line voltage | On-Grid Inverter / Hybrid Inverter |
| vgridCa Deprecated | Decimal | V | Grid CA line voltage | On-Grid Inverter / Hybrid Inverter |
| pac | Decimal | kW | Instantaneous active power | On-Grid Inverter / Hybrid Inverter |
| ppvInput | Decimal | kW | Total PV input power | On-Grid Inverter / Hybrid Inverter |
| totalPvPower | Double | kW | Total PV input power | Hybrid Inverter |
| vpv1 | Decimal | V | PV1 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv2 | Decimal | V | PV2 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv3 | Decimal | V | PV3 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv4 | Decimal | V | PV4 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv5 | Decimal | V | PV5 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv6 | Decimal | V | PV6 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv7 | Decimal | V | PV7 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv8 | Decimal | V | PV8 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv9 | Decimal | V | PV9 voltage | On-Grid Inverter / Hybrid Inverter |
| vpv10 | Decimal | V | PV10 voltage | On-Grid Inverter / Hybrid Inverter |
| ipv1 | Decimal | A | PV1 current | On-Grid Inverter / Hybrid Inverter |
| ipv2 | Decimal | A | PV2 current | On-Grid Inverter / Hybrid Inverter |
| ipv3 | Decimal | A | PV3 current | On-Grid Inverter / Hybrid Inverter |
| ipv4 | Decimal | A | PV4 current | On-Grid Inverter / Hybrid Inverter |
| ipv5 | Decimal | A | PV5 current | On-Grid Inverter / Hybrid Inverter |
| ipv6 | Decimal | A | PV6 current | On-Grid Inverter / Hybrid Inverter |
| ipv7 | Decimal | A | PV7 current | On-Grid Inverter / Hybrid Inverter |
| ipv8 | Decimal | A | PV8 current | On-Grid Inverter / Hybrid Inverter |
| ipv9 | Decimal | A | PV9 current | On-Grid Inverter / Hybrid Inverter |
| ipv10 | Decimal | A | PV10 current | On-Grid Inverter / Hybrid Inverter |
| ppv1 | Integer | kW | Pv1 input power | On-Grid Inverter / Hybrid Inverter |
| ppv2 | Integer | kW | Pv2 input power | On-Grid Inverter / Hybrid Inverter |
| ppv3 | Integer | kW | Pv3 input power | On-Grid Inverter / Hybrid Inverter |
| ppv4 | Integer | kW | Pv4 input power | On-Grid Inverter / Hybrid Inverter |
| ppv5 | Integer | kW | Pv5 input power | On-Grid Inverter / Hybrid Inverter |
| ppv6 | Integer | kW | Pv6 input power | On-Grid Inverter / Hybrid Inverter |
| ppv7 | Integer | kW | Pv7 input power | On-Grid Inverter / Hybrid Inverter |
| ppv8 | Integer | kW | Pv8 input power | On-Grid Inverter / Hybrid Inverter |
| ppv9 | Integer | kW | Pv9 input power | On-Grid Inverter / Hybrid Inverter |
| ppv10 | Integer | kW | Pv10 input power | On-Grid Inverter / Hybrid Inverter |
| totalBackupP | Decimal | kW | Total power on the Backup side | Hybrid Inverter |
| backupAv | Decimal | V | Backup side phase A voltage | Hybrid Inverter |
| backupAi | Decimal | A | Backup side phase A current | Hybrid Inverter |
| backupAf | Decimal | Hz | Backup side phase A frequency | Hybrid Inverter |
| backupAp | Decimal | kW | Backup side phase A power | Hybrid Inverter |
| backupBv | Decimal | V | Backup side phase B voltage | Hybrid Inverter |
| backupBi | Decimal | A | Backup side phase B current | Hybrid Inverter |
| backupBf | Decimal | Hz | Backup side phase B frequency | Hybrid Inverter |
| backupBp | Decimal | kW | Backup side phase B power | Hybrid Inverter |
| backupBq | Double | kVar | Backup side phase B reactive power | Hybrid Inverter |
| backupBs | Double | kVA | Backup side phase B apparent power | Hybrid Inverter |
| backupCv | Decimal | V | Backup side phase C voltage | Hybrid Inverter |
| backupCi | Decimal | A | Backup side phase C current | Hybrid Inverter |
| backupCf | Decimal | Hz | Backup side phase C frequency | Hybrid Inverter |
| backupCp | Decimal | kW | Backup side phase C power | Hybrid Inverter |
| backupCq | Double | kVar | Backup side phase C reactive power | Hybrid Inverter |
| backupCs | Double | kVA | Backup side phase C apparent power | Hybrid Inverter |
| pLoad | Decimal | kW | Total load power | On-Grid Inverter / Hybrid Inverter |
| pload Deprecated | Decimal | kW | Total load power | On-Grid Inverter / Hybrid Inverter |
| ploadPhaseA | Double | kW | Phase A load power | Hybrid Inverter |
| ploadPhaseB | Double | kW | Phase B load power | Hybrid Inverter |
| ploadPhaseC | Double | kW | Phase C load power | Hybrid Inverter |
| invtAp | Decimal | kW | Phase A active power | Hybrid Inverter |
| invtAq | Integer | kVar | Phase A reactive power | Hybrid Inverter |
| invtAs | Integer | kVA | Phase A apparent power | Hybrid Inverter |
| invtBp | Decimal | kW | Phase B active power | Hybrid Inverter |
| invtBq | Integer | kVar | Phase B reactive power | Hybrid Inverter |
| invtBs | Integer | kVA | Phase B apparent power | Hybrid Inverter |
| invtCp | Decimal | kW | Phase C active power | Hybrid Inverter |
| invtCq | Integer | kVar | Phase C reactive power | Hybrid Inverter |
| invtCs | Integer | kVA | Phase C apparent power | Hybrid Inverter |
| soc | Decimal | % | Remaining Battery Power | Hybrid Inverter |
| soh | Decimal | % | Battery Health Strength | Hybrid Inverter |
| cumulativeChargingNum | Double | — | Cumulative number of charge | Hybrid Inverter |
| cumulativeDischargeNum | Double | — | Cumulative number of discharge | Hybrid Inverter |
| batteryStatus | Number | — | Battery status 0 - Normal 1 - Abnormal | Hybrid Inverter |
| totalBatPower | Decimal | — | Total battery power | Hybrid Inverter |
| batteryP | Decimal | kW | Battery charge/discharge power, P > 0 discharge, P < 0 charge | Hybrid Inverter |
| vchargingCutoff | Integer | V | Charging cut-off voltage | Hybrid Inverter |
| vdischargeCutoff | Integer | V | DisCharging cut-off voltage | Hybrid Inverter |
| batteryV | Decimal | V | Battery Voltage | Hybrid Inverter |
| minCelVoltageId | Double | — | Minimum Cell Voltage Id | Hybrid Inverter |
| minCellVoltage | Decimal | V | Minimum Cell Voltage | Hybrid Inverter |
| maxCellVoltageId | Double | — | Maximum Cell Voltage Id | Hybrid Inverter |
| maxCellVoltage | Decimal | V | Maximum Cell Voltage | Hybrid Inverter |
| minCellTemperatureId | Double | — | Minimum Cell Temperature Id | Hybrid Inverter |
| minCellTemperature | Decimal | ℃ | Minimum Cell Temperature | Hybrid Inverter |
| maxCellTemperature | Decimal | ℃ | Maximum Cell Temperature | Hybrid Inverter |
| maxCellTemperatureId | Double | — | Maximum Cell Temperature Id | Hybrid Inverter |
| bmsPackTemperature | Decimal | ℃ | Battery temperature | Hybrid Inverter |
| batteryI | Decimal | A | Battery Current | Hybrid Inverter |
| iChargingLimit | Decimal | A | Charging current limit | Hybrid Inverter |
| iDischargeLimit | Decimal | A | Discharge current limit | Hybrid Inverter |
| bmsInsulationTestValue | Double | kΩ | Insulation monitoring status | Hybrid Inverter |
| bmsStatus | Double | — | BMS status | Hybrid Inverter |
| bmsErrorCode | Double | — | BMS error code | Hybrid Inverter |
| bmsWarnCode | Double | — | BMS warn code | Hybrid Inverter |
| bmsAlarmCode | Double | — | BMS alarm code | Hybrid Inverter |
| bmsWarning | Double | — | BMS warning code | Hybrid Inverter |
| batteryMode | Double | — | 1:Charging 0:Discharging | Hybrid Inverter |
| pf | Double | — | Power factor | On-Grid Inverter / Hybrid Inverter |
| epvDay | Decimal | kWh | Energy storage device generation for the day | Hybrid Inverter |
| eMeterTotalBuy | Decimal | kWh | The total amount of electricity purchased by the meter | Hybrid Inverter |
| emeterTotalBuy Deprecated | Decimal | kWh | The total amount of electricity purchased by the meter | Hybrid Inverter |
| eMeterTotalSell | Decimal | kWh | The total amount of electricity sold by the meter | Hybrid Inverter |
| emeterTotalSell Deprecated | Decimal | kWh | The total amount of electricity sold by the meter | Hybrid Inverter |
| eInverterUseDay | Decimal | kWh | Daily inverter power consumption | Hybrid Inverter |
| einverterUseDay Deprecated | Decimal | kWh | Daily inverter power consumption | Hybrid Inverter |
| eTotalLoadUplink | Decimal | kWh | Total load uplink power | Hybrid Inverter |
| etotalLoadUplink Deprecated | Decimal | kWh | Total load uplink power | Hybrid Inverter |
| eTotalPv | Decimal | kWh | Total power generation from energy storage devices | Hybrid Inverter |
| etotalPv Deprecated | Decimal | kWh | Total power generation from energy storage devices | Hybrid Inverter |
| eLoadUpDay | Decimal | kWh | Daily load uplink power | Hybrid Inverter |
| eloadUpDay Deprecated | Decimal | kWh | Daily load uplink power | Hybrid Inverter |
| ebackupDay | Double | kWh | Daily Backup load electricity consumption | Hybrid Inverter |
| eSellDay | Decimal | kWh | Daily electricity sales | Hybrid Inverter |
| esellDay Deprecated | Decimal | kWh | Daily electricity sales | Hybrid Inverter |
| eBuyDay | Decimal | kWh | Daily purchased electricity | Hybrid Inverter |
| ebuyDay Deprecated | Decimal | kWh | Daily purchased electricity | Hybrid Inverter |
| ebuyTotal | Double | kWh | Total amount of electricity purchased | Hybrid Inverter |
| esellTotal | Double | kWh | Total amount of electricity sold | Hybrid Inverter |
| eloadUseDay | Double | kWh | Daily load electricity consumption | Hybrid Inverter |
| etotalBackupLoad | Double | kWh | Total Backup load electricity consumption | Hybrid Inverter |
| etotalLoadUse | Double | kWh | Total load electricity consumption | Hybrid Inverter |
| eBatteryChargeDaily | Decimal | kWh | Daily battery charge | Hybrid Inverter |
| eBatteryDischargeDaily | Decimal | kWh | Daily Battery Discharge | Hybrid Inverter |
| eTotalBatteryCharge | Decimal | kWh | Total Battery Charge | Hybrid Inverter |
| etotalBatteryCharge Deprecated | Decimal | kWh | Total Battery Charge | Hybrid Inverter |
| eTotalBatteryDischarge | Decimal | kWh | Total Battery Discharge | Hybrid Inverter |
| etotalBatteryDischarge Deprecated | Decimal | kWh | Total Battery Discharge | Hybrid Inverter |
| eTotalInverterUse | Decimal | kWh | Total inverter power consumption | Hybrid Inverter |
| etotalInverterUse Deprecated | Decimal | kWh | Total inverter power consumption | Hybrid Inverter |
| eDay | Decimal | kWh | On-grid devices power generation on the same day | On-Grid Inverter |
| eTotal | Decimal | kWh | Total power generation from on-grid devices | On-Grid Inverter |
Server time format: yyyy-MM-dd HH:mm:ss Z
"—" in the Unit column indicates that the field has no unit (non-numeric field or status/identifier field).
Charger Data
| Field | Type | Unit | Remark | Device Type |
|---|---|---|---|---|
| chargerControlMode | Number | — | Charger control mode 0 Inverter control 1 Standalone operation | Hybrid Inverter |
| chargerRunStatus | Number | — | Charger status | Hybrid Inverter |
| vChargerPhaseA | Decimal | V | Charger phase A voltage | Hybrid Inverter |
| vChargerPhaseB | Decimal | V | Charger phase B voltage | Hybrid Inverter |
| vChargerPhaseC | Decimal | V | Charger phase C voltage | Hybrid Inverter |
| iChargerPhaseA | Decimal | A | Charger phase A current | Hybrid Inverter |
| iChargerPhaseB | Decimal | A | Charger phase B current | Hybrid Inverter |
| iChargerPhaseC | Decimal | A | Charger phase C current | Hybrid Inverter |
| pChargerPhaseA | Decimal | W | Charger phase A output power | Hybrid Inverter |
| pChargerPhaseB | Decimal | W | Charger phase B output power | Hybrid Inverter |
| pChargerPhaseC | Decimal | W | Charger phase C output power | Hybrid Inverter |
| pChargerTotal | Decimal | W | Charger total output power | Hybrid Inverter |
| eChargerSession | Decimal | kWh | Charger energy of the current session | Hybrid Inverter |
| chargerSessionDuration | Number | Min | Duration of the current charging session | Hybrid Inverter |
| eChargerDaily | Double | kWh | Charger daily energy | Hybrid Inverter |
| eChargerTotal | Double | kWh | Charger total energy | Hybrid Inverter |
| chargerChargeCount | Double | — | Number of charges Restarts from 1 after reaching 60000 | Hybrid Inverter |
| chargerStartMethod | Number | — | Charging start method | Hybrid Inverter |
| chargerEndReason | Number/null | — | Charging end reason | Hybrid Inverter |
Charger Status
| Value | Description |
|---|---|
| 0 | Not plugged in |
| 1 | Standby |
| 2 | Charging |
| 3 | Discharging |
| 4 | Charging complete |
| 5 | Charging fault |
| 6 | Charging warning |
| 7 | Scheduled charging |
| 8 | Charging paused |
Charging End Reasons
| Value | Description |
|---|---|
| 0 | Default value * |
| 1 | Stopped by card |
| 2 | Stopped from app |
| 3 | Other reason * |
| 4 | Stopped by schedule |
| 5 | EVC load limit |
| 6 | Ended by vehicle |
| 7 | Stopped by unplugging |
| 8 | Stopped due to fault |
| 9 | Other reason * |
| 100 | Other reason * |
* Values 0, 3, 9, and 100 are not valid end reasons and should not be treated as indicators of charge completion.
Charging Start Methods
| Value | Description |
|---|---|
| 0 | Default |
| 1 | Card swipe |
| 2 | App immediate |
| 3 | App scheduled |