Device Alarm Codes
This document lists the alarm codes for inverters, EV chargers, and batteries. Look up the codes returned in the alarms field of the realtime data API and the history data API in the tables below.
Alarm types: Fault (device stopped or malfunctioning, handle with priority), Warning (device running degraded, troubleshoot as soon as possible), Info (status notification only).
Inverter Alarms (46)
| Code | Type | Name | Solution |
|---|---|---|---|
| E001 | Fault | DC BUS Over Voltage | 1. Check whether the DC input voltage exceeds the inverter maximum operating voltage. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E002 | Fault | Mains Lost | No grid connection detected. The AC switch or circuit may be open. 1. Check whether the grid voltage is normal. 2. Check whether the AC wiring is correct and whether the AC circuit breaker is in normal condition. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E003 | Fault | Grid Voltage Fault | The inverter has detected that the AC voltage exceeds the safety regulation limits. 1. Verify that the safety code is correct. 2. Check whether the AC-side wiring is correct. 3. Check whether the cross-sectional area of the AC cable is sufficient. Confirm that the wire size matches the power rating. If excessive line impedance causes the grid voltage to rise beyond the limit, replace the cable with one of a larger cross-section. 4. If permitted by the utility company, widen the inverter's voltage protection range. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E004 | Fault | Grid Frequency Fault | The inverter has detected that the AC frequency exceeds the safety regulation limits. 1. Verify that the safety code is correct. 2. Occasional frequency anomalies may occur due to grid fluctuations; the inverter will automatically resume operation once the grid recovers. 3. If permitted by the utility company, widen the inverter frequency protection range. 4.If the issue persists, please contact your installer or our technical support team for further assistance. |
| E005 | Fault | DCI Fault | 1. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E006 | Fault | ISO Over Limitation | An insulation fault was detected on the DC side due to low resistance to ground. 1. Check whether the PV modules, batteries, DC cables, and connectors are damaged or have water ingress. 2. Use an insulation resistance tester to measure the insulation impedance between the DC side and the ground. The measured value should not be lower than 500 kΩ. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E007 | Fault | GFCI Fault | An excessive ground leakage current was detected on the inverter. 1. Check whether the PV modules, batteries, DC cables, and connectors are damaged or have water ingress. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E008 | Fault | PV Over Voltage | PV input voltage exceeds inverter's allowable upper limit. 1. Reduce the number of PV modules to ensure that the open-circuit voltage of each string is lower than the inverter's maximum operating voltage 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E009 | Fault | Over Temperature | 1. Check whether the inverter installation location is well ventilated. 2. Try shutting down the inverter for a period of time and restarting it after the temperature drops. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E010 | Fault | N-PE Check Fault | 1. Check whether the grounding wire on the backup side is properly connected. 2. In off-grid mode, if grounding of the neutral line on the backup side is not required, disable this function. 3.If the issue persists, please contact your installer or our technical support team for further assistance. |
| E011 | Fault | Inverter Over Freq | Abnormal load on the backup side during off-grid operation. 1.Check whether there is an impact load on the back-up side and whether the load power is too high. 2.Check whether back-up side is short circuit. |
| E012 | Fault | BAT Voltage Fault | 1. The inverter has detected a sudden change in battery voltage. If it does not recover automatically, restart the battery. 2. Reduce the number of batteries to ensure that the maximum battery voltage is lower than the inverter maximum operating voltage. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E013 | Fault | Backup Voltage Fault | 1. Check whether any generation equipment is connected on the backup side. 2. Restart the inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E014 | Fault | HW Fault | 1. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E015 | Fault | Backup Over Power | 1. Verify that the total load on the backup side does not exceed the inverter maximum output capacity. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E016 | Fault | Inverter Over Voltage | 1. Check whether there are surge loads or whether the backup load power exceeds the rated inverter output. 2. Check whether there is a short circuit on the backup side. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E017 | Fault | Inverter Over Current | 1. Check whether there are surge loads or whether the backup load power exceeds the rated inverter output. 2. Check whether there is a short circuit on the backup side. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E018 | Fault | FLASH Fault | 1. The issue may be caused by interference. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E019 | Fault | SCI Fault | 1. The issue may be caused by interference. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E020 | Fault | SPI Fault | 1. The issue may be caused by interference. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E021 | Fault | E2 Fault | 1. The issue may be caused by interference. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E022 | Fault | GFCI Device Fault | 1.Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E023 | Fault | AC Transducer Fault | 1. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E024 | Fault | Relay Check Fail | 1. Use a multimeter to measure the voltage between the neutral and ground wires. If the voltage exceeds 10 V, it indicates an abnormal connection on the grid side neutral or ground line. 2.Restart the inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E025 | Fault | Internal Fan Fault | 1.Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E026 | Fault | External Fan Fault | 1. Check whether the fan is blocked by foreign objects. If so, clean it. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E027 | Fault | Comm. Sampling Fault | 1. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E028 | Fault | DC BUS Voltage Low | 1.Check whether the DC voltage is normal. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E029 | Fault | Meter Comm Fault | Inverter–meter communication error detected. 1. Check whether the communication cable between the inverter and the meter is properly connected. 2. Verify that the energy meter model is compatible. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E030 | Fault | DC Arc Fault | 1. Check the PV side for loose terminals or damaged cables that may cause arcing. 2.Restart the inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E031 | Fault | AFCI Comm Fault | 1. The issue may be caused by interference. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E032 | Fault | Bus Voltage Hard Fault | 1. Check whether the DC input voltage exceeds the inverter maximum operating voltage. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E033 | Fault | DC BUS Voltage Unbalance | 1.Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E034 | Fault | Backup Over Current | 1.Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E035 | Fault | Backup Box Fault | 1. Check whether the backup box(EDA) is connected correctly. If it is not connected, disable the backup box detection function. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E037 | Fault | Phase Order Err | 1. Check whether the grid wiring matches the configured phase sequence. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E038 | Fault | Third-party Meter Comm Fault | 1. Check the communication cable between the inverter and the meter. 2. Verify that the energy meter model is compatible. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W001 | Warning | Other Faults | 1. Restart the inverter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W002 | Warning | PV Power Low | 1. Check whether the PV connection and PV energy generation are normal. 2. Check the battery operating status and confirm that the battery output capability is not limited. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W003 | Warning | BAT Power Low | When off-grid or during grid disconnection, if the battery status is abnormal or unable to supply power: 1. Check battery power cable connections. 2. Check the battery circuit breaker, switch, or fuse. 3. Check for alarms or protections and restart the battery after resolving the issue. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W004 | Warning | DC BUS Voltage Unblance | 1.Restart the inverter. 2.If the issue persists, please contact your installer or our technical support team for further assistance. |
| W005 | Warning | Phase Lock Fault | 1. Check whether the grid connection is correct. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W006 | Warning | BAT Invalid | When off-grid or during grid disconnection, if the battery status is abnormal or unable to supply power: 1. Check battery power cable connections. 2. Check the battery circuit breaker, switch, or fuse. 3. Check for alarms or protections and restart the battery after resolving the issue. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W007 | Warning | High-impedance Control Fault | 1. High impedance in cables or the system may cause three-phase unbalance oscillation. Disable the three-phase unbalance function. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W008 | Warning | Comm Cmd Off | 1. The inverter may have stopped due to E-stop, watchdog, RCR, or DRM commands. Check related settings and command statuses. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W009 | Warning | Meter Comm Fail | 1. Check the communication cable between the inverter and the meter. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
EV Charger Alarms (23)
| Code | Type | Name | Solution |
|---|---|---|---|
| E300 | Fault | Emergency button has been pressed | 1. Please remove the charge gun out of the door and rotate the emergency button clockwise to recover. If LED light indicator changes to green or blue, the fault has been recovered. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E301 | Fault | Emergency button has been pressed | 1. Please remove the charge gun out of the door and rotate the emergency button clockwise to recover. If LED light indicator changes to green or blue, the fault has been recovered. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E302 | Fault | Grounding Fault | EV charger station has not been properly grounded. 1. Please contact your installer or our technical support team to measure voltage between N line and PE line: Proper grounding:[0,40]V Poor grounding:[40,90]V Ungrounded:[90,130]V Line L & N reversed and poor grounding:[130,180]V Line L & N reversed:[180,220]V |
| E303 | Fault | Charge Port Door Open | Please contact your installer or our technical support team for further assistance. |
| E304 | Fault | CP Error | 1. Please check if there is any damage of charger cable. 2. Re-plug in the charge gun to make sure the well contact between gun and EV. 3. Charge another EV to check if somethign wrong with the charge gun. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E305 | Fault | Meter Error | Hardware issue. 1. Please contact technical support to check meter chip and its circuit. |
| E306 | Fault | Under Voltage | AC input voltage < 150V. 1. Please contact technical support to check if distribution system is normal. If necessary, contact local utility institution. |
| E307 | Fault | Over Voltage | AC input voltage > 275V. 1. Please contact technical support to check if distribution system is normal. If necessary, contact local utility institution. |
| E308 | Fault | Relay Sticking | Hardware issue. 1. Please contact contact your installer or our technical support team for further assistance. |
| E309 | Fault | GFCI Protection | 1. Please check if there is any damage of charger cable. 2. Please check if any shortage of PE in EV. 3. Charge another EV to check if somethign wrong with the charge gun. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E310 | Fault | Over Current | Charging current is greater than the one allowed by EV charger. 1. Please reduce min. charging current allowed by EV. Make sure it's smaller than the one allowed by EV charger. |
| E311 | Fault | Communication Fault with Inverter | 1. Please check if the connection between inverter and EV charger is well and proper. 2. Please ensure that EV charger is compatible with the inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E312 | Fault | Other Faults | Please contact your installer or our technical support team for further assistance. |
| E313 | Fault | Main Circuit Breaker Trip Protection | Due to the current out of breaker rated range, EV charger stops charging 3 times during 30 minutes. 1. The system would keep monitoring surplus power in following 30 minutes. If surplus power can support restart of EV charger, EV charger would restart charging the car with the min power and alarm would be removed automatically. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E314 | Fault | Communication Fault of Partial DC Power Modules | Please contact your installer or our technical support team for further assistance. |
| E315 | Fault | Communication Fault of All DC Power Modules | Please contact your installer or our technical support team for further assistance. |
| E316 | Fault | Over Temperature | Excessive ambient temperature or a short circuit. 1. Please make sure EV charger is sheltered to avoid direct sunlight. 2. Please make sure EV charger station away from heat source. 3. Please ensure ambient temperature lower than 40℃. 4. Please restart EV charger if ambient temperature lower than 40℃ and check if the issue has been recovered after 1 min. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W301 | Warning | EVC Power Limited for INV Abnormality | Due to the INV abnormality, EV charger reports corresponding alarm and charges EV under pre-set strategy. 1. EV charger will operate under pre-set strategy until inverter recovers. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W300 W304 | Warning | System Overcurrent Warning | EV charger stops charging due to the home load and EV charging power exceed the breaker rated power. 1. In green mode with grid able, if it occurs 1 or 2 times within 30 minutes, the system will continuously monitor the available residual power within 30 minutes after charging stop. When there is sufficient power the charging process will be restarted automatically at the minimum charging power. The alarm is cleared simultaneously. 2. In fast mode, charging process will be restarted automatically once there is sufficient power. The alarm is cleared simultaneously. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W305 | Warning | EVC Charging not Available | The charging process can't be started due to insufficient remaining system power. 1.The charging process can be started once the system remaining power is sufficient. The alarm is cleared simultaneously. 2.If the issue persists, please contact your installer or our technical support team for further assistance. |
| W306 | Warning | Green Power Insufficient | In Green mode with grid disable, the system available power can't meet the minimum charging power. 1. The charging process will be restarted when PV and Battery power is sufficient. The alarm is cleared simultaneously. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I300 | Info | Vehicle Disconnection | Due to the protection strategy of EV during charging, EV charger suspends charging. 1. EV charger will continue charging once EV protection removed. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I301 | Info | EVC Charging Interrupted | Due to the abnormal issues (such as poor contact, unplugging the gun,etc.), EV charger stops charging. 1. Re-start the charging after confirmation of the contact and connection. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
Battery Alarms (138)
| Code | Type | Name | Solution |
|---|---|---|---|
| E400 | Fault | BMS Comm Fault -BAT1 | Inverter–BMS communication error detected. 1. Check if battery model is correctly selected. 2. Check if comm. connection and line sequence of BMS and inverter is properly. 3. Check if the battery is under normal status. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E431 | Fault | Abnormal Battery Voltage -BAT1 | There is significant deviation between battery voltage measured by inverter and that reported by the BMS . 1. Check if battery power cables are properly and securely connected. 2. Check if battery circuit breaker, switch, or fuse is abnormal. 3. Check if battery under alarm or protection. Clear faults and reboot the battery after reinstallation or rebooting. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E432 | Fault | Abnormal BAT Parallel No. -BAT1 | |
| E489 | Fault | BMS Comm Fault -BAT2 | |
| E490 | Fault | Abnormal Battery Voltage -BAT2 | |
| E491 | Fault | Abnormal BAT Parallel No. -BAT2 | |
| E404 | Fault | BAT Voltage Sensor Fault | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E405 | Fault | BAT Temp. Sensor Fault | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E406 | Fault | BAT Internal Comm Fault | There might be something wrong with battery internal comm. circuit. 1. Check comm. cable between battery module and controller. 2. Reboot the battery. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E407 | Fault | Input OV Fault | Input voltage on battery is too high. 1. Check if power cables are incorrectly connected to other source. 2. Check if there is malfunction of inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E408 | Fault | Input Reversed or Short Fault | Input polarity is reversed. 1. Check if power cables are reversely connected. 2. Check if there is malfunction of inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E409 | Fault | Control Device Check Fault | There might be something wrong with battery relay. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E410 | Fault | Cell Damaged Fault | Cell is severely over-discharged. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E411 | Fault | Shutdown Circuit Fault | Can not switch off the system. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E412 | Fault | BMIC Fault | Sensor chip is abnormal. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E413 | Fault | BAT Internal Bus Fault | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E414 | Fault | Self-checking Fault | Self-checking failed. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E415 | Fault | Safety Function Fault | Chip self-checking failed. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E416 | Fault | ISO Fault | Isolation is too low. 1. Turn off the whole system. 2. Check if any damage or breakage in devices, cables, terminals, etc. 3. Check if any circuit shorted by foreign matters. 4. Reboot battery after removing anomalies. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E492 | Fault | ||
| E493 | Fault | ||
| E487 | Fault | Fatal Error | Fatal error in battery system. Please contact your installer or battery manufacturer for further assistance immediately. |
| E417 | Fault | Cell UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if there is obvious cell voltaqe deviation.If there is obvious cell voltaqe deviation,fully charge and discharge the battery for several times. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E418 | Fault | Cell OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E419 | Fault | Cluster UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if load power is oversized. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E420 | Fault | Cluster OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E421 | Fault | Charge UT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E422 | Fault | Charge OT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E423 | Fault | Discharge UT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E424 | Fault | Discharge OT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E425 | Fault | Charge OC | 1. Check if current limitation of battery decreases cause of temp, SOC, etc 2. Check if inverter does not charge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E426 | Fault | Discharge OC | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not discharge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E427 | Fault | Battery Module UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Reboot and then charge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E428 | Fault | Battery Module OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E429 | Fault | Heater OT-L3 | 1. Check if terminal temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down terminal and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E430 | Fault | Abnormal Leakage | 1. Turn off the whole system. 2. Check if any damage or breakage in devices, cables, terminals, etc. 3. Check if any circuit shorted by foreign matters. 4. Reboot battery after removing anomalies. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E488 | Fault | Severe Error | Fatal error in battery system. Please contact your installer or battery manufacturer for further assistance immediately. |
| I400 | Info | Cell UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if there is obvious cell voltaqe deviation.If there is obvious cell voltaqe deviation,fully charge and discharge the battery for several times. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I401 | Info | Cell OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I402 | Info | Cluster UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if load power is oversized. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I403 | Info | Cluster OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I404 | Info | Charge UT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I405 | Info | Charge OT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I406 | Info | Discharge UT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I407 | Info | Discharge OT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I408 | Info | Charge OC | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not charge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I409 | Info | Discharge OC | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not discharge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I410 | Info | Battery Module UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Reboot and then charge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I411 | Info | Battery Module OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I412 | Info | Terminal OT | 1. Check if terminal temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down terminal and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I413 | Info | Abnormal Fan | Fan of battery module is abnormal. 1. Turn off the battery and check if power cable of fan is connected correctly. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I414 | Info | Abnormal Leakage | 1. Turn off the whole system. 2. Check if any damage or breakage in devices, cables, terminals, etc. 3. Check if any circuit shorted by foreign matters. 4. Reboot battery after removing anomalies. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| I416 | — | Heater OT-L1 | |
| I415 | Info | General Info. | Tips of battery systerm status. Nothing needs to processed. |
| W400 | Warning | Cell UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if there is obvious cell voltaqe deviation.If there is obvious cell voltaqe deviation,fully charge and discharge the battery for several times. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W401 | Warning | Cell OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W402 | Warning | Cluster UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if load power is oversized. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W403 | Warning | Cluster OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W404 | Warning | Charge UT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W405 | Warning | Charge OT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W406 | Warning | Discharge UT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W407 | Warning | Discharge OT | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W408 | Warning | Charge OC | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not charge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W409 | Warning | Discharge OC | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not discharge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W410 | Warning | Battery Module UV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Reboot and then charge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W411 | Warning | Battery Module OV | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W412 | Warning | BMU Offline | BMU in battery module is offline. 1. Turn off the battery system. 2. Please contact your installer or our technical support team for further assistance. |
| W413 | Warning | BMCU Offline | BMCU in controller is offline. 1. Turn off the battery system. 2. Please contact your installer or our technical support team for further assistance. |
| W414 | Warning | SN Change of Module | Battery module(s) changed. 1. Check if any battery module is removed or added. 2. Check if SOC and voltage of all the battery modules are the same when added. 3. Please contact your installer or our technical support team for further assistance. |
| W415 | Warning | Abnormal Change of Cluster Voltage | 1. Check if power cable is connected correctly. 2. Check if abnormal change of voltage and SOC. 3. Reboot battery after removing anomalies. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W416 | Warning | Abnormal Cluster △V | 1. Check if power cable is connected correctly. 2. Check if abnormal change of voltage and SOC. 3. Check if battery mode and number in each cluster is the same. 4. Reboot battery after removing anomalies. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W417 | Warning | Abnormal Module △V | 1. Check if power cable is connected correctly. 2. Check if abnormal change of voltage and SOC. 3. Reboot battery after removing anomalies. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W425 | Warning | Heating Circuit Temperature Sensor Error | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W426 | Warning | Heating Circuit Checking Error | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W427 | Warning | Abnormal Voltage of Heating Ciruit | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W429 | Warning | Heater OT-L2 | |
| W428 | Warning | General Warning | General Warning for battery system, which might lead to performance limitation. Please contact your installer or battery manufacturer for further assistance immediately. |
| E433 | Fault | Fire Alarm | Presence of fire, smoke,or other fire-related emergencies are detected. Immediately ensure all on-site systems enter E-stop and check the alarm validity. If alarm is TRUE: 1. Evacuate all non-essential personnel at once. 2. Contact qualified technicians or fire-rescue immediately. 3. Establish an isolation perimeter without delay. |
| E434 | Fault | Flooding Alarm | There is too much water accumulated in the system, which triggers the flood alarm. Immediately ensure all on-site systems enter E-stop and check the alarm validity. If alarm is TRUE: 1. Evacuate all non-essential personnel at once. 2. Contact qualified technicians or fire-rescue immediately. 3. Establish an isolation perimeter without delay. |
| E435 | Fault | Acess Alarm | Access control detect the disclosure of cabinet door. 1. Check if the cabinet door is opened without authorization. if it is an unauthorized opening, close the door with confirmation of the safety of on-site personnel and system. 2. Check if the access control is functioning normally. if there is faulty, replace it immediately. |
| E436 | Fault | Emergency Stop | System emergency stop is triggered manually or automatically due to the present or potential hazard to system or personnel. 1. Check if there is present and/or potentional hazard to personnel or system. If it is true, excute those solutions of corresponding alarm. 2. Check if emergency-stop was activated accidentally. If it was a false trigger, reset the E-stop with confirmation of the safety of on-site personnel and system. |
| E437 | Fault | UPS Battery Damaged | UPS battery has been damaged due to misuse or other causes. 1. Reboot the UPS. 2. If problem remains, contact manufacturer after-sales for solution. |
| E438 | Fault | UPS OT | UPS is over temperature due to operating environment,overcurrent, etc. 1. Check if UPS temperature is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the charging current or decrease the load power. 4. Reduce the enviroment temp. to cool down UPS. |
| E439 | Fault | Abnormal Extinguisher Comm. | 1. Check if any damage in comm. cables or ports. 2. Check on-site wiring and comm. settings are correct. 3. Check if any magnetic interference is present. 4. Reboot the system. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E440 | Fault | Abnormal Air Conditioner Alarm | 1. Check if any damage in the air conditioner. 2. Check the error code on the panel of air conditioner. 3. Check if any malfunction of temp. sensors. 4. Check if any magnetic interference is present. 5. Reboot the system. 6. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E441 | Fault | Abnormal EMS-BMS Comm. | 1. Check correct selection of battery ID. 2. Check the working status of battery. 3. Check if any damage in comm. cables or ports. 4. Check on-site wiring and comm. settings are correct. 5. Check if any magnetic interference is present. 6. Reboot the system. 7. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E442 | Fault | Abnormal EMS-Fire-SYS Comm. | 1. Check if any damage in comm. cables or ports. 2. Check on-site wiring and comm. settings are correct. 3. Check if any magnetic interference is present. 4. Reboot the system. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E443 | Fault | Abnormal EMS-Air Conditioner Comm. | 1. Check if any damage in comm. cables or ports. 2. Check on-site wiring and comm. settings are correct. 3. Check if any magnetic interference is present. 4. Reboot the system. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E444 | Fault | Cell UV-L3 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if there is obvious cell voltaqe deviation.If there is obvious cell voltaqe deviation,fully charge and discharge the battery for several times. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E445 | Fault | Cell OV-L3 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E446 | Fault | Cluster UV-L3 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if load power is oversized. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E447 | Fault | Cluster OV-L3 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E448 | Fault | Charge UT-L3 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E449 | Fault | Charge OT-L3 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E450 | Fault | Discharge UT-L3 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E451 | Fault | Discharge OT-L3 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E452 | Fault | Charge OC-L3 | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not charge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E453 | Fault | Discharge OC-L3 | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not discharge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E454 | Fault | Battery Module UV-L3 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Reboot and then charge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E455 | Fault | Battery Module OV-L3 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E456 | Fault | BAT Voltage Sensor Fault | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E457 | Fault | BAT Temp. Sensor Fault | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E458 | Fault | BAT Internal Comm Fault | There might be something wrong with battery internal comm. circuit. 1. Check comm. cable between battery module and controller. 2. Reboot the battery. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E459 | Fault | Input OV Fault | Input voltage on battery is too high. 1. Check if power cables are incorrectly connected to other source. 2. Check if there is malfunction of inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E460 | Fault | Input Reversed Fault | Input polarity is reversed. 1. Check if power cables are reversely connected. 2. Check if there is malfunction of inverter. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E461 | Fault | P+ Relay Checking Fault | There might be something wrong with battery relay. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E462 | Fault | P- Relay Checking Fault | There might be something wrong with battery relay. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E463 | Fault | Cell Damaged Fault | Cell is severely over-discharged. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E464 | Fault | Shutdown Circuit Fault | Can not switch off the system. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E465 | Fault | BMIC Fault | Sensor chip is abnormal. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E466 | Fault | BAT Internal Bus Fault | Battery internal bus is abnormal. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E467 | Fault | Self-checking Fault | Self-checking failed. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E468 | Fault | Safety Function Fault | Chip self-checking failed. 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E469 | Fault | ISO Fault | Isolation is too low. 1. Turn off the whole system. 2. Check if any damage or breakage in devices, cables, terminals, etc. 3. Check if any circuit shorted by foreign matters. 4. Reboot battery after removing anomalies. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W418 | Warning | Abnormal Cluster △V | 1. Check if power cable is connected correctly. 2. Check if abnormal change of voltage and SOC. 3. Check if battery mode and number in each cluster is the same. 4. Reboot battery after removing anomalies. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E470 | Fault | Terminal OT | 1. Check if terminal temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down terminal and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E471 | Fault | CAN2 Comm. Fault | Inverter–battery BMS communication error detected. 1. Check if the selected battery model is correct. 2. Verify that communication between the BMS master and the inverter is properly established. 3. Check if the battery is in normal stauts. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E472 | Fault | CAN1 Comm. Lost | Inverter–battery BMS communication error detected. 1. Check if the selected battery model is correct. 2. Verify that communication between the BMS master and the inverter is properly established. 3. Check if the battery is in normal stauts. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E473 | Fault | Abnormal DCDC Switch | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E474 | Fault | Duplicate CAN addr. | 1. Reboot the battery. 2. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E475 | Fault | Cell UV-L2 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if there is obvious cell voltaqe deviation.If there is obvious cell voltaqe deviation,fully charge and discharge the battery for several times. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E476 | Fault | Cell OV-L2 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E477 | Fault | Cluster UV-L2 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Check if load power is oversized. 4. Reboot and then charge the battery immediately. 5. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E478 | Fault | Cluster OV-L2 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E479 | Fault | Charge UT-L2 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E480 | Fault | Charge OT-L2 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E481 | Fault | Discharge UT-L2 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Increase the enviroment temp. to warm up battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E482 | Fault | Discharge OT-L2 | 1. Check if battery temp. is reasonable. 2. Check if any malfunction of temp. sensors. 3. Reduce the enviroment temp. to cool down battery and then reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E483 | Fault | Charge OC-L2 | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not charge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E484 | Fault | Discharge OC-L2 | 1. Check if current limitation of battery decreases cause of temp, SOC, etc. 2. Check if inverter does not discharge according to current limitation. 3. Reboot battery after checking or adjusting configuration of inverter. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E485 | Fault | Battery Module UV-L2 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-charging or unstopped discharging. 2. Check if the external source (PV, utility grid, diesel generator, etc.) stop working, which leads to inexecution of forced-charging or unstopped discharging. 3. Reboot and then charge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| E486 | Fault | Battery Module OV-L2 | 1. Check if there is any malfunction or incorrect configuration of inverter, which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 2. Check if any unsuitable setting and/or configuration , which leads to inexecution of forced-discharging or inexecution protection according to charging voltage limitation. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W419 | Warning | Inconsistent Cell qty. | 1. Check if different battery pack used. 2. Check if there is internal comm. Malfuntion in any battery pack. 3. Reboot and then discharge the battery immediately. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W420 | Warning | Cluster(s) under Forced-charging | 1. Check if any battery under forced-charging 2. Reboot after forced-charging finished. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W421 | Warning | Cluster(s) under Upgrading | 1. Check if any battery under upgrading. 2. Reboot after upgrading finished. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W422 | Warning | Master Polling | 1. Check if any battery under information-poll. 2. Check if it back to normal after minutes. 3. Reboot the battery. 4. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W423 | Warning | Cluster(s) turned off Manually | 1. Check if any battery is turned-off manually. 2. Reboot the battery. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |
| W424 | Warning | Emergency Stop Triggered of Cluster(s) | 1. Check if any battery is turned-off manually. 2. Reboot the battery. 3. If the issue persists, please contact your installer or our technical support team for further assistance. |